1.
Korean Journal of Gastrointestinal Endoscopy ; : 366-370, 2008.
Article in Korean | WPRIM | ID: wpr-181419

ABSTRACT

Esophageal cancer may induce progressive dysphagia. Insertion of a self-expandable metallic stent is widely used to relieve dysphagia. There are previous case reports that have described the use of membrane-covered stents to seal esophageal perforations. Complications of the use of an esophageal stent include bleeding, fistula formation, perforation, pain, tumor ingrowth and migration of the stent. A perforation may occur during or after the insertion of a stent from a contact ulcer due to the sharp ends of the metallic stents. We report a case of esophageal perforation after the insertion of a membrane-covered esophageal stent, which showed perforation at the middle portion of stent due to expansion of the stent. The perforation was sealed without surgical treatment or additional stent insertion.


Subject(s)
Deglutition Disorders , Esophageal Neoplasms , Esophageal Perforation , Esophagus , Fistula , Hemorrhage , Stents , Ulcer
SELECTION OF CITATIONS
SEARCH DETAIL